A, laundry room design principles
 
1, laundry equipment graphic design principles
 
The division standard: laundry room area of 100 square meter = = rooms + X square meters
 
Production areas: check sorting coding region packaging,Elution baked into a water production area;Pressing the whole shape of 
 
washing ironing area;Elution drying ironing plastic as one of the dry cleaning production areas.

Assist area: office, material area;Transport corridor and parking areas;The dressing rooms, health area;Boiler room, air compressor 
 
area;Distribution of lighting area.

Cloth grass deposit area: linen storage area;Distribution area;Sewing area.
 
Taken the above data are for reference only, actual size will be subject to on-site equipment layout.
 
2, laundry room construction technical requirements
A power supply: the total power in three-phase five wire laying.
 
B cold water pipeline: in cold water head of plated pipe laying of DN75 heat, pressure, 3-4 kg/C temperature 10 to 30 .
C hot water pipe: (hot water head of hot dip pipe laying, pressure, 3-4 kg/C temperature 65-85 .
D steam pipe, steam head laid on DN75 seamless welded steel pipe, pressure 6-10 kg/C, 140  saturated steam.
E air pressure pipeline: to DN15 hot air director of plated pipe laying, pressure 6-10 kg/C.F the cooling pipes: condensed water head in 
 
DN40 welded pipe laying, chang PaiKou zero pressure.
G on exhaust duct: have good exhaust device, requirements in volume between 1200-1800, room temperature control in 25-35 .Air 
 
conditioning air humidity below 80%, recommended.
H drainage: drains are divided into two parts: equipment at the back of the drain for the open trench, trench cover use embossing plate 
 
cover;Size is 300 x 400, additional settling basin.
I atrioventricular ground: use 1 floor tile of pottery clay, in order to increase water imbibition and anti-skid function.
 
 
3, laundry room, other technical requirements
A water quality: expressed in hardness, on the basis of PPM. Copies per 1 million water contains calcium carbonate.It is one of the 
 
important measure of quality of laundry, with hard water washing, make clothes have not good consequences, not only but also more 
 
than the soft water consumption of detergent.
Index: PPM control between 72-144, as the soft water, good water conforms to the laundry.It is recommended that increase the 
 
softening water equipment.
Valve B: laundry equipment of all kinds of models requires the use of different steam pressure and hydraulic pressure, therefore, should 
 
be according to the requirements of equipment on the branch pipe add pressure reducing valve, safety valve, check valve, steam trap, 
 
by-pass valve, etc., all of the pipe valves and pipe fittings, due to the switch every day, especially the steam valves, influenced by often 
 
open pass, high temperature and high pressure, easy to form dripping phenomenon, therefore, must choose d shape without seal valve 
 