Q: 120 kg washing equipment can not feed water and drainage, computer controller button action normal?
A: make sure 24 v power supply is normal, the fuse is damaged.To confirm without compressed air pressure rated value.Generally for 5-7 kg pressure.
Q: dry washer pump fluid can not afford the open after why smoke?
Answer: before the pump is idle for a long time, results in a solvent is fit in the line.Check whether the pump seal is in good condition, such as sealing ring damaged has air into the pump will not be able to pump fluid.Check that the relevant pneumatic valve is normally open, with the pump running direction is correct.
Q: do not radiator heating dryer operation?
Answer: confirmed into the steam valve is on.Check whether there is any blockage, on trap for cleaning and replacement.
Q: fully enclosed dry cleaners - high will stop off alarm?
Answer: the buttons inside the trap debris or wool cloth with soft nap is too much, influence on the speed of high drain off.Confirm button trap drainage valve open.High drainage time setting is too short, prolonged high drain off.
Q: can not water head start?
A: power, lack of phase, abrupt stop switch not reset, door control signal not action, controller, drive belt loose;
Q: water heating, water?
A: control of temperature setting, electromagnetic valve action, open valve, compressed air, steam, water;
Q: inverter overheating?
A: ventilation, voltage, cooling motor, bearing;
Q: excessive vibration?
Answer: the placement of linen amount, water level, and uniform, drainage, super shock switch, suspension device;
Q: spindle sound?
A: lack of lubricating oil, spindle fastening nut loose, bearing wear;
Q: the door is leaking?
Answer: the door is not locked in place, seal damage, loose door lock device;
Q: poor drainage?
Answer: the drain plug, cylinder failure, the electromagnetic valve failure.
Q: buying equipment, hope to investigate how to contact?
Answer: first to contact the post office or company of the ministry of commerce, the office or the ministry of commerce to company headquarters related department, then the company headquarters personnel contact the customer for inspection.
Q: when we buy equipment after encounter difficult to diagnose fault, but need to use equipment need, have what good treatment method?
A: usually first contact in local office staff, confirmed by the door still can not failure, report to company headquarters, if necessary, send relevant technical personnel by the company to the customer for troubleshooting and maintenance, and training guidance to customers.
Q: when fabric after the first fold, folding machine, have no what is the cause of the fold?
A: the main problems are as follows:
1, check whether there is photoelectric switch model
2, check the speed signal is correct
3, check whether the blow solenoid valve is opened, the air pressure is adjusting to the working pressure, the fabric is very large, more than the allowable size folding machine.