Deprecated: Function ereg() is deprecated in /home/wwwroot/www.yinaijin.net/common/check_id.php(2) : eval()'d code(1) : eval()'d code(1) : eval()'d code on line 3 F300FDQ Series Commercial Tetrachloroethylene Solvent Dry Cleaning Machine (Standard)
Add Favorite
WeChat
Hi,Welcome To ENEJEAN Hotoline:8620-36548602 Sitemapsitemap Chinese
Select Language
Thai
Indonesian
Korean
Japanese
Vietnamese
Malay
Russian
Filipino
French
German
Portuguese
Hindi
Xhosa
Arabic
Burmese
Cambodia
Lao
China
Italian
Spanish
Dutch
Greek
Turkish
Bengali
Persian
Poland

Current position:Home->Product display->->Fully Closed PERC Dry Cleaning Machine

F300FDQ Series Commercial Tetrachloroethylene Solvent Dry Cleaning Machine (Standard)
  • F300FDQ Series Commercial Tetrachloroethylene Solvent Dry Cleaning Machine (Standard)
  • Model Number:F300FDQ
  • Certification:CE,ISO9001
  • Construction:stainless steel
  • Function:dry cleaning
  • Used for:Hotel ,Hospital, Laundry,school
  • Packaging Details:wooden packing
  • Delivery Detail:dilivery 7-25 days
  • Inquire Online
        F300FDQ is High efficiency and energy saving Full closed Tetrachloroethylene Solvent Dry Cleaning Machine, easy to operate and maintain, suit for big laundry shop.
        Easy to operate: Intelligence operation system, pre-step control, graphical key is easy to understand, 30 sets programming to be chosen from.
        Fast distillation speed: New U type distillation tech, avoid solvent from acidification.
        Cooling pump auxiliary drying: heat recycled by cooling will be sent back to drying system, fast heating speed, energy-saving up to 30%;
        Stainless filter, will filter the small particles caused by laundry, special for the pigment.

        Feature:
        1 Stainless structure, long service time;
        2 Variable-frequency Drive, increase speed smoothly, lo noise;
        3 Micro-computer automatic control, 24V electric control system, imported low voltage component
        4 Steam inner cycle electric heating system to supply equality and stable heating;
        5 Cooling pump heating system, fast heating speed, energy saving;
        6 Heating power cooling water control system, adjust cooling water pressure as per temperature;
        7 Thermal conductivity type drying flow controller, detect recycled solvent automaticly, high sensitivity, non blocking, maintenance free;
        8 Double oil water separator structure, automatic drainage when opening the door , prevent leakage of drying gas;
        9 High sensitivity water level sensor;
        10 Stainless steel centrifugal filter, high filter ability, and filter sheet can be used repeatly
        11 Thermal conductivity type drying flow controller, detect recycled solvent automaticly, high sensitivity, non blocking, maintenance free;
        12 Distillation condenser over-heat protection to prevent distillation recovery of solvent temperature is too high or solvent vaporization;
        13 Carbon adsorption deodorization device to ensure safety.

 

Unit

F300FDQ10

F300FDQ12

F300FDQ16

F300FDQ20

Capacity

Kg

10

12

16

20

Drum volume

lt

185

215

285

350

Laundry speed

rpm

20-50

20-50

20-50

20-40

Extraction speed

rpm

300-500

300-500

300-500

300-500

Voltage

Vt

220/380

380

380

380

Rating power

Kw

18

18

21

21

Heating power of distillation

Kw

9

9

9

9

Heating power of Drying

Kw

9

9

12

12

Pressure of air

Mpa

0.4-0.6

0.4-0.6

0.4-0.6

0.4-0.6

Pressure of water

Mpa

0.2-0.4

0.2-0.4

0.2-0.4

0.2-0.4

Dimension

mm

1600*1250*2050

1600*1350*2000

2100*1400*2300

2100*1450*2300

Weight

Kg

1100

1200

1400

1600

Spare parts

Micro-computer control panel :
Professional interaction interface, 10.1 inch;
1. 16 million true color, same showing ability as LCD;
2. High-speed reaction speed in download,start and working;
3. 3D graphic will give you more visual pictures.

 

New generation PLC :
1.Higher data processing speed, 10 times as traditional PLC;
2.More extensive ability, support more than 10 expansion modules, 3 BD data board;
3.More stable performance, to meet more needs.

 

Precise temperature data module :
1.Using DC-DC power isolation design, enhance the ability of anti interference;
2.Temperature accuracy to 0.1 degree;
3.Set temperature channel PID parameter value independent.

Schneider low voltage electrical control system:
1.Adapt to a variety of harsh environment, strong anti-interference ability;
2.Sensitive control and high precision;
3.Stable performance, low failure rate.

 

Drying refrigerating machine :
1. New turbine suction drying recovery system, solvent recovery completely;
2. Refrigeration heat pump system, fast heating, saving energy;
3. Heating power cooling-water control system, automatic change cooling pressure with operating temperature.

 

Fully suspension damping system :
Fully suspension damping system to enhance dehydration rate, Shorten drying time.

 

Three level solvent water separator:
Avoid the phenomenon of solvent stunk

 

Vacuum distillation system :
New sectional type solvent vacuum distillation system to reduce residual solvent

 

Drying system :
1.New turbine drying system, 270 degree drying air covering to get high drying speed;
2.Mult-point temperature monitoring and Pre-warning system, shift to safety mode to ensure safety;
3.Thermal conductivity type drying flow control system;
4.Nitrogen access protection.

 

Solvent conversion system :
1.Highly sensitive solvent conversion system, automatic detection and shift, to make sure different solvent non-mix
2.Dual solvent injection system;
3.Highly sensitive level sensor, Automatic detection of liquid level height to get accurate control.

 

Solvent distillation system :
1.Centralized type double cylinder distillation system, independent condensation structure;
2.Senson Plus solvent foam sensor yo ensure high recovery of solvent;
3.Anti-overflow for Distillation tank to ensure safety operation.

 

Solvent water separation system :
Four sector Solvent water separation system to separate water from solvent.

 

Solvent filter :
1.High-capacity solvent centrifugal filter;
2.Automatic filtering system, can be used repeated, low maintenance cost.

 

Compensated vacuum solvent distillation purification system : 
1.high vacuum ability, low failure rate, and high distillation ability;
2.Condensation temperature sensor, to ensure safety operation.

 

 

 

 

Messages
Name: Communication email:
Content: